AutoMeg 4-2500 Automatic Test Systems

Electrical Parameters

Continuity

Current

5mA to 1000mA Programmable 1mA

Voltage

1V to 30V Programmable to 1V

High Voltage DC

Voltage

25V to 2500V Programmable 5V

Current

0.1uA to 4000uA

High Voltage AC (when fitted)

Voltage

25V to 1500V RMS @ 50 Hz Programmable to 5V

Current

1uA to 5000uA

Typical Test Performance

Continuity

Switching speed > 50000 points per second
0.05s per established connection
0.05s shorts test per point

Insulation and Hi-pot

Programmable Ramp, Pre Dwell and Dwell times.
Minimum 0.1s per point

Measurements

Continuity

0.002 to 100K
Accuracy 0.5% +/- 0.002 @ 1000mA
Resolution 0.001

DC Insulation

5K to 1000M Accuracy 5%

AC Hi-pot

1uA to 5000uA Accuracy 5%

Interface

32 off 4 wire (Kelvin) Test points per board
Maximum 256 test points per sub-rack, maximum 512 sub-racks, 1311072

Connection via high specification McMurdo Red Range sockets

Options

Extended continuity range up to 1M
Increased continuity test current up to 10A
Custom voltages up to 100KV
External Instruments and customised electrical tests
Communication with other devices
Customised import facility for programme creation